Fadhlan HD

jasa assessment fire risk analysis

Cara Melakukan Uji Fungsi FM200 Tanpa Perlu Memanggil Teknisi

Sebagai pemilik Fire Suppression Systems, Anda juga bisa melakukan sendiri kegiatan uji fungsi FM200 tanpa harus memanggil teknisi atau Fire Suppression Engineer. Seperti apa cara melakukannya dan bagaimana prosedur pengujiannya, sebenarnya sangat mudah sekali. Bahkan Office Boy di kantor Anda pun bisa melakukannya.

Cara Melakukan Uji Fungsi FM200 Tanpa Perlu Memanggil Teknisi Read More »

Workshop refilling station ReedFOX Clean Agent Gas Fire Suppression Systems. Isi ulang gas refill FM200, HFC227ea, refill FK5112, refill Novec, refill Inertgas

Prosedur Refilling Isi Ulang FM-200

Dengan memahami alur proses prosedur refilling isi ulang FM-200, akan memudahkan Anda untuk menyiapkan segala sesuatu yang berkaitan dengan proses internal di perusahaan Anda. Mulai dari mengatur jadwal personil yang bertugas untuk mendampingi, izin dan perizinan di lokasi kerja, mengatur transportasi dan akomodasi, menjadwalkan pelatihan, hingga proses administrasi lainnya.

Prosedur Refilling Isi Ulang FM-200 Read More »

Pengumuman Novec-1230 berhenti produksi

Novec-1230 Berhenti Produksi Mulai Tahun 2025

3M mengumumkan bahwa Novec-1230 berhenti produksi mulai akhir tahun 2025, pengumuman tersebut mereka unggah pada 20 Desember 2022.

Dalam penyataannya 3M akan menghentikan produksi dan berhenti menggunakan bahan kimia fluorochemical yang mengandung zat per- and polyfluoroalkyl substance (PFAS), salah satunya adalah Novec-1230.

Novec-1230 Berhenti Produksi Mulai Tahun 2025 Read More »

bg blog fm200 pemadam api data center server

Sistem Proteksi Kebakaran untuk Data Center

Data centres are provided with fire suppression and detection measures to protect critical data and help minimise business interruption. At least part of the protection may be provided by a gas extinguishing or water sprinkler/water mist systems. The consideration of a particular type of system has historically been determined by specialist consultants, who in turn

Sistem Proteksi Kebakaran untuk Data Center Read More »

clean agent gas

Special Hazard Fire Suppression

Special hazard fire suppression technologies differ from fire sprinklers in how they mitigate damage from fire. These innovative solutions use gaseous or chemical agents to rapidly quell fires by absorbing heat or displacing required oxygen—but without catastrophic losses of building contents and business continuity. Facility designers, owners and managers should understand the best practices for

Special Hazard Fire Suppression Read More »

chemical formula HFC-227ea FM-200 Fire Suppression Systems

Pengertian Clean Agent Gas Menurut NFPA 2001:2022

Definisi terbaik untuk menjelaskan apa itu Clean Agent Gas adalah berdasarkan deskripsi yang ada di dalam NFPA 2001. Yaitu, Clean Agent Gas adalah bahan pemadam api yang berbentuk gas atau mudah menguap, yang tidak menghantarkan listrik dan tidak meninggalkan jejak residu saat menguap. “A volatile or gaseous fire extinguishant that is electrically nonconducting and does not leave a residue upon evaporation“.

Pengertian Clean Agent Gas Menurut NFPA 2001:2022 Read More »

Scroll to Top